2027 New EU Machinery Regulation from January 2027: is the change history of your PLC software traceable? Machinery Regulation 2027: Learn more →

Built by PLC engineers.
For PLC engineers.

CodeShuttle brings the tools of modern software development into your TIA Portal – with respect for everything that matters in automation: safety, traceability and full control over every change.

Synchronisation

Two sides. One truth. Your decision.

CodeShuttle keeps your TIA project and a folder of text files in sync in both directions. Every run has three steps: scan, preview, apply – and you always decide before anything is applied.

  • Direction proposal per object: TIA → folder, folder → TIA or skip
  • Bulk actions per device: "all TIA→folder", "all folder→TIA", "skip all"
  • Unchanged objects hidden – you only see what really matters
  • Device selection: only the controllers and panels you need right now
  • Sync scope per project: stored in the sync folder, the same for everyone in the team
  • Type and language per row, such as FB · SCL or FC · LAD – even before the first export

Conflicts stop everything

If an object changed in TIA and in the folder, nothing is applied – nothing else either – until you have decided every conflict. There is deliberately no "always prefer TIA" rule.

Deletes only when you say so

A proposed delete always arrives skipped. It is only carried out once you explicitly choose the delete direction.

No noise after compiling

Compiling only changes timestamps in TIA. CodeShuttle checks the actual content and reports only real changes – no phantom differences.

Compile before sync

Optionally, TIA compiles each device before comparing. Inconsistent objects are detected, locked and never deleted by accident. If an import – say a renamed UDT element – breaks dependent blocks, CodeShuttle locks exactly those until they are fixed in TIA.

Block numbers are kept

A header line such as // CodeShuttle-Block: FB 12 carries the number through export and back into TIA – for SCL and STL too.

Saving stays your call

CodeShuttle changes the open TIA session but never saves the project itself. You keep the final say.

Scope

What CodeShuttle synchronises.

Every category can be switched on and off individually. Where Openness sets limits, we tell you openly – locked rows stay visible and state their reason.

Area Objects TIA → folder Folder → TIA
PLC blocks OB, FB, FC and DB in SCL, STL, LAD, FBD and GRAPH – as .scl, .awl, .db or SimaticML ✓✓
Types & tables PLC data types (UDT), tag tables, watch and force tables ✓✓
Software Units Every software unit with its blocks, data types and tables in a group of its own (TIA Portal V19 and from V21) ✓✓ creates missing units, never deletes one; safety units stay in TIA
F-blocks User-written F-FB, F-FC and F-DB in F-LAD, F-FBD and F-STL (from TIA Portal V19 with STEP 7 Safety) ✓ (from V19)✓ as a deliberately chosen F-change
HMI (WinCC classic) Screens, pop-ups, slide-ins, templates, global screen elements, screen overview, HMI tag tables, text and graphic lists, VB scripts, connections ✓✓ updates existing objects and, after asking, creates missing screens, templates, HMI tag tables and text lists
WinCC Unified Scripts, text, system text and graphic lists, tag tables – and, if you like, the screens (TIA Portal V20 and V21) ✓✓ scripts & lists (graphic lists from V21), missing script modules are created; screens and tag tables are not allowed by Openness
Multiuser Engineering Local sessions of a Multiuser project, compared and synced like a single project (from TIA Portal V17) ✓✓ from V19; never objects marked by colleagues; check-in stays in TIA
Device details DeviceDetails.xml per device: IP addresses, order number, firmware, PROFINET data and module identification ✓— documentation only

Not synchronised: know-how-protected blocks, system blocks generated by TIA for the safety program, F-blocks from libraries, and drives (SINAMICS). An HMI screen that TIA cannot export appears as a locked row with its reason instead of a recurring error.

Diff view

See what changed – before it is applied.

CodeShuttle compares LAD, FBD and STL graphically, network by network – the way you know the blocks from TIA. Plus SCL with properties and interface as tables, GRAPH as a step sequence, data blocks and PLC data types.

  • Graphical, side by side or inline – in the sync list, in the history and in the conflict dialog
  • Tag, watch and force tables open as a table
  • Zoom and pan: Ctrl+mouse wheel zooms the networks, wide networks are panned with the mouse
  • In a window of its own, for instance on a second screen – several comparisons at once
  • Changes only with adjustable context lines (default: 3, like Git)
  • Resolve a conflict with one click: "take TIA" or "take folder"
  • External tools: WinMerge, Beyond Compare, KDiff3 and VS Code are detected automatically; path and arguments are configurable
  • Device details as a field table instead of raw XML – a changed IP or firmware at a glance
Safety

F-blocks – with the respect safety engineering deserves.

From TIA Portal V19 with STEP 7 Safety, CodeShuttle also versions your safety program. Every change to it is a deliberate decision – and it is documented.

Never preselected

An F-change – import into TIA or delete in TIA – is never selected by CodeShuttle, not even by a bulk button. You review it in the diff view and select it on its row.

Collective signature before & after

From TIA Portal V21, after every run involving F-blocks – even an aborted one – CodeShuttle shows the collective F-signature of each fail-safe CPU before and after the run. If it changes, it points out that a new acceptance may be required.

Import is verified

After every F-import, CodeShuttle checks that the block exists in TIA and is still in an F-language – otherwise the step counts as failed. CodeShuttle never asks for a password.

Usability

Several TIA versions. One tool.

  • Automatic detection of every running TIA Portal instance – even without a visible window
  • Switch instances with one click without restarting; optionally with process ID
  • Recently opened: your last ten projects with one click – if no matching TIA Portal is running, CodeShuttle starts one itself, always in the project's version
  • Sync folder remembered per project – everything is back the next time you connect
  • German and English, light or dark theme; settings split into "Application" and "Project"
  • Log console in your language, filtered by info, warning and error
  • Updates from within the app – current with one click, important updates are clearly recommended

Open a folder – without TIA

View the history, fetch the team state, resolve a conflict: a sync folder opens even on a computer without TIA Portal. Ideal for project managers, service and acceptance.

Merge office and site

The folder comparison puts two states without a shared history side by side – office and commissioning, say. Decide row by row, take over, or save as a new folder.

Command line for automation

An optional second package for scripts, build servers and AI agents: the same rules as the app, the result as JSON, description and author as parameters.

Technology & IT

Lean, secure and IT-friendly.

Architecture & security

  • Official interface: TIA Portal Openness – no changes to your TIA installation
  • No Siemens libraries bundled: CodeShuttle uses the Openness libraries of your installed TIA version
  • Isolated background process: an error on the Siemens side never takes down the user interface
  • Your project data stays with you: only the Git destination you choose receives your code
  • Credentials encrypted under your Windows account, never in the log
  • Centrally manageable: update check can be disabled by group policy

System requirements

Operating systemWindows 10 / 11, .NET Framework 4.8
TIA PortalV14 SP1, V15, V15.1, V16, V17, V18, V19, V20, V21
OpennessAccount in the "Siemens TIA Openness" group, CodeShuttle allowed in TIA
SafetyFor F-blocks: from TIA Portal V19 with STEP 7 Safety, collective F-signature from V21
MultiuserLocal sessions from TIA Portal V17 (V17/V18 export only)
InstallationPer user, no administrator rights
GitBuilt in – no separate installation needed
NetworkOnly for licence activation, updates and your team repository – after that CodeShuttle also runs offline

Let's talk about your PLC development.

In a free discovery call via Microsoft Teams, we get to know how you work in TIA Portal today and work out together where CodeShuttle adds the most value for you. No obligation, directly with the maker.

Free · approx. 30 minutes · Microsoft Teams · no obligation
Book a discovery call